La Rochere - Vertical Fire Resistant Glazings
| Fire Resistance Classification according to AS1530.4-1997 | -/60/- Integrity only Prevents the spread of fire, smoke & hot glasses for 60 minutes. |
-/90/- Integrity only Prevents the spread of fire, smoke & hot glasses for 90 minutes. |
-/120/- Integrity only Prevents the spread of fire, smoke & hot glasses for 120 minutes. |
-/60/30 Integrity & Insulation Prevents the spread of fire, smoke & hot glasses for 60 minutes & penetration of thermal radiation for 30 minutes. |
-/90/60 Integrity & Insulation Prevents the spread of fire, smoke & hot glasses for 90 minutes & penetration of thermal radiation for 60 minutes. |
| Dwg No. | 02 & 03 | 11 & 12 | 13 & 14 | 15 & 16 | 17 & 18 |
| Glass Block Size & Type | La Rochere 190 x 190 x 80. All types. |
La Rochere 300 x 300 x 100 & 190 x 190 x 100. All types. |
La Rochere 2 skins of -/90/-, 100mm blocks. All types. |
La Rochere 190 x 190 x 100 dbl 50mm block. Type TF30. |
La Rochere 190 x 190 x 150 triple 50mm block. Type TF60. |
| Maximum Height | 3380mm | 3000mm | 3000mm | 3000mm | 3000mm |
| Maximum Width | Unlimited | 6000mm | 6000mm | 4000mm | Unlimited |
| Thickness of Glass Block Wall | 80mm | 100mm | Minimum 250mm | 100mm | 150mm |
| Weight per square metre (10mm joint) | 105kg | 125kg | 125kg each skin | 160kg | 215kg |
| Test Certificates | Efectis Test Report No. 08-V-064 | CSTB Test Report No. 87.26109 | CSTB Test Report No. 87.26109 | CTICM Test Report No. 02-V-299 | CTICM Test Report No. 05-V-136 |
| Diagrams | Download -/60/- diagram | Download -/90/- diagram | Download -/120/- diagram | Download -/60/30 diagram | Download -/90/60 diagram |
CSIRO Assessment FCO-2779